XSDR Reset Cabinets technical overview

The XSDR Series

Technical Data for XSDR Floor Life Reset Cabinets

Features

  • Ext. Dimensions (WHD)
  • Int. Dimensions of each chamber (WHD)
  • Capacity per chamber
  • Weight
  • Power Consumption
  • No of Shelves per chamber
XSDR Reset Cabinets

XSDR 702-24

  • Ext. dimensions (WHD) 700 x 2060 x 850 mm
  • Int. dimensions (WHD) 582 x 696 x 685 mm
  • Effective capacity 260 L
  • Weight 138 kg
  • Power consumption 30 W/h per chamber
  • Number of shelves 2 (additional shelves optional)

Performance test

XSDR reset cabinets performance test
Instrument9x Hygroclip HC2AS 
Accuracy of dew point sensor± 0,3° C at + 20° C (+ 68° F)
Location of sensorsEvery corner + center
Ambient conditionsHum. 50 ± 5% rH, 22°C ± 2°C, Pressure 994 ± 20 hPa
Door openings2 door openings, 15 sec

Display

Type 4 touchscreen display
SettingsMenu language options
Nominal humidity value
Humidity value alarm 
Delay humidity alarm
Nominal temperature value (in combination with heater)
Temperature alarm (in combination with heater)
Delay temperature alarm (in combination with heater)
Sensor offset 
Password protection
Floor life reset timer
Manual regeneration
SpecificationsVoltage supply (supplied by Drying Unit) 24 VAC/DC, 350 mA
Input touchscreen
TFT Color LCD 4,3”
Controllable brightness
Ethernet connection

Drying unit U-2000 series

U-2000-dry-unit
ControlAdjustable with control panel type 4
Dehumidifying temperature10 – 60° C
Electric supply230 VAC (120 VAC optional)
Dimensions (LWH)260 x 380 x 100 mm
Weight8.1 kg

Rotronic sensor HC2A-S

Rotronic sensor HC2A-S

Based on the Airchip 3000 Technology, the HygroClip 2 probes can be used for control of temperature and humidity. The HygroClip 2 probes can be configured with the ROTRONIC HW4 software and share the following features:

  • Measurement of relative humidity and temperature
  • Programmable automatic sensor test with fail safe mode and sensor drift compensation

Free Totech Viewer

Totech Viewer software
FeaturesWriting of climate data, door openings and alarms to SD card
Transfer data through Ethernet to PC (history data)
User friendly display of all relevant data
Data processing in MSExcel
Seamless documentation
Excellent process safety
Floor life reset cabinets - XSDR 702-24

XSDR 702-24

Technical Drawings &
Downloads